Production Capabilities


 Material
 For single and doublesided Tg 135°C/Tg 170°C
 For multilayer Tg 170°C
 Min thickness for DS&ML 0,36mm
 Min inner layer thickness 0,1mm
 Min prepreg thickness 0,063mm
 Max thickness for DS&ML 2,4mm
 Materials on stock See here
 Max layer count 24

Holes and wires

 Min hole drilled 0,1mm
 Min blind via 0,1mm
 Drill tolerance +/- 0,1mm
 Max plugged hole with solder mask 0,4mm
 Min annular ring on inner layer 0,1mm
 Min annular ring on outer layer 0,05mm
 Aspect ratio for blind vias 1:1
 Min distance drill to drill 0,15mm
Min distance drill to plane (vias 0,2mm -0,4mm) Min distance drill to plane (vias 0,1mm/0,15mm/0,5mm and up) 0,15mm (on inner layer) 0,2mm (on inner layer)
 Min landing pad for blind via 0,3mm (on innerlayer)
 Min inner layer wire and gap 0,075mm
 Min outer layer wire and gap 0,06mm
 Min distance from wire to border 0,2mm
 Min distance from V-cut to border 0,4mm V-cut calculator

Solder mask and legend print

 Solder mask colors green, black, white, blue, red
 Solder mask thickness 20-25µ
 Min opening from pad 0,05mm
 Min dam width 0,075mm for green color; 0,150mm for other colors
NB! The vias with diameter 0,4 mm and smaller may contain solder mask residue!
Legend print colors  white, black
Min line on legend print  0,1mm
Min distance from pad to legend  0,150mm
Tolerance of alignment  ±25µ

NB! The markings with line thickness smaller than 0,1mm will be increased automatically!

NB! The markings on the solder mask openings will be removed!


Pads plating

 Hot air levelling Felder SN99Ag+  5-20µ minimum thickness of material 0,8mm; plated slot annular ring min. 0,5mm
 Immersion gold ENIG  Ni 3-6µ; Au 0,05-0,125µ plated slot annular ring min. 0,2mm

Mechanical

Min router bit 0,2mm
Max router bit 2,5mm
Routing tolerance ±0,1mm
V-cut 30°; min core 0,2mm
Min material thickness for V-cut 0,8mm
V-cut tolerance ±0,3mm
Min board dimensions 10 x 10mm
Max board dimensions 360 x 460mm
Blind and buried vias
Blind slots (Z-milling)
Backdrilling
Yes, see here
Yes, see here
Yes, see here

Design rules


Outer layer

 Min pad for via  min. hole + 0,2mm
 Min pad for component holes  min. hole + 0,3mm
 Min conductor and space for foil 12µ  0,065mm
 Min conductor and space for foil 18µ  0,075mm
 Min conductor and space for foil 35µ  0,125mm
 Min conductor and space for foil 70µ  0,25mm
 Min distance between copper plane / hole  0,125mm
 Min distance between pad and copper  0,075mm
 Min distance from copper to V-cut center  0,4mm
 Min distance between wire and border  0,2mm

Inner layer

 Min pad min. hole + 0,3mm
 Min distance from copper plane and hole 0,2mm
 Min blind via landing pad via + 0,2mm
 Min conductor and space for foil 18µ 0,075mm
 Min conductor and space for foil 35µ 0,125mm
 Min conductor and space for foil 70µ (prepreg thickness at least 0,2mm) 0,25mm

If our design rules do not meet your requirements please consult with our Sales Assistants!